Spin Basket - Toshiba AW-SD150SBA Service Manual

Fully automatic washing machine
Table of Contents

Advertisement

Unless otherwise specified, reassembling is to be performed in the reverse procedures of disassembling.
Part Name
Illustration
(16) Pulsator

(17) Spin basket

assembly
Repair Procedures Description in
Be careful not to drop the washer which is located
under the blade.
Note 1) Be careful not to damage the spin tub when
Note 2) Be careful not to lose the washer which is
Note 3) Reassembly need put washer on shaft
(Photo 63)
1 Remove the rear cover. (6 screws)
2 Remove the lead wire clamps (1 places) from the
external case. Then remove the lead wire bundle from
the cord holder (by takeoff 1 screw).
3 Remove the tapping screws (2 pcs) on the back side
of top cover. And remove the circle VKHHW VLGH DQG
VFUHZV IROORZLQJ WKH SURFHGXUHV VWDWHG LQ
(Photo 64)
of (10).
4 Pull up the top cover from cabinet.
5 Let the whole top cover lean against the wall, etc. to
let it stand on the external case.
At this time, put a towel between the lead wire and
external case to prevent lead wires from being cut. In
(Photo 65)
addition, put a towel on the air tube of the water level
sensor to prevent it from being damaged with the top
end of the external case. Pay attention not to deform
the safety lever.
6 Release 12 hooks to remove the tub cover.
7 Remove the pulsator following the procedures stated
in (16).
(Photo 66)
8 Remove 4 hexagon bolts.
(Photo 67)
– 5 –
pulling out the pulsator from the spin tub.
located under the blade.
before lay down pulsator.
shows notes.
(Photo 64)
10 ~ 11
(Photo 6)
(Photo 6)
(Photo 6)