A-6-4 Manual Control Level; A-6-5 Monitor/Setting Item Level; A-6-6 Advanced Function Setting Level - Omron E5CC User Manual

Digital
Hide thumbs Also See for E5CC:
Table of Contents

Advertisement

*2
Transfer output type
Set Point
Set Point During SP
Ramp
PV
MV (Heating)
MV (Cooling)
Valve opening
*2.1
Initialized when the transfer output type is changed.
Initialized if the input type, temperature unit, scaling upper/lower limit, or SP upper/lower limit is changed
when the transfer output type is SP, ramp SP, or PV.
(When initialized by the initializing settings, it is initialized to 100.0/0.0.)
*3
PRST (Program Start) can be set even when the Program Pattern parameter is set to OFF, but the
function will be disabled.
*4
This function can be set for heating/cooling control or for floating control for Position-proportional Models,
but the setting will be disabled.
A-6-4
Manual Control Level
Parameters
Manual MV
−5.0 to 105.0 (standard)
−105.0 to 105.0 (heating/cooling)
−5.0 to 105.0 (position-proportional)
*1
When the Manual MV Limit Enable parameter is set to ON, the setting range will be the MV lower limit to the MV upper
limit.
*2
The valve opening is monitored for floating control or for close control with the Direct Setting of Position-proportional MV
parameter set to OFF.
A-6-5
Monitor/Setting Item Level
The contents displayed vary depending on the Monitor/Setting 1 to 5 (advanced function setting
level) setting.
A-6-6
Advanced Function Setting Level
Parameters
Characters
init
Parameter Initialization
mspu
Number of Multi-SP
Points
spru
SP Ramp Time Unit
rest
Standby Sequence
Reset
sb1n
Auxiliary Output 1
Open in Alarm
sb2n
Auxiliary Output 2
Open in Alarm
sb3n
Auxiliary Output 3
Open in Alarm
sb4n
Auxiliary Output 4
Open in Alarm
hbu
HB ON/OFF
E5@C Digital Temperature Controllers User's Manual (H174)
Setting (monitor) range
SP lower limit to SP upper limit
SP lower limit to SP upper limit
Temperature input: Input setting range lower
limit to Input setting range upper limit
Analog input: Scaling lower limit to Scaling
upper limit
Standard: −5.0 to 105.0
Heating/cooling: 0.0 to 105.0
0.0 to 105.0
−10.0 to 110.0
Setting (monitor) value
*1
*2
*1*2
Setting (monitor) value
OFF, FACT
OFF(1), 2 to 8
S: EU/second
M: EU/minute
H: EU/hour
Condition A, condition B
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
OFF, ON
Default*4.1
(transfer output upper/lower
limits)
SP upper limit/lower limit
SP upper limit/lower limit
Input setting range upper/lower
limit
Scaling upper/lower limit
100.0/0.0
100.0/0.0
100.0/0.0
Default
Unit
0.0
%
Display
off, fact
OFF
off, 2 to 8
OFF
s, m, h
M
a, b
Condition A
n-o, n-c
N-O
n-o, n-c
N-O
n-o, n-c
N-O
n-o, n-c
N-O
off, on
ON
A Appendices
Unit
EU
EU
EU
%
%
%
A
Default
Unit
None
None
None
None
None
None
None
None
None
A - 23

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5acE5ec

Table of Contents