5.5 Setting Example

How to calculate the input pulse frequency division ratio
Use the following formula to calculate the input pulse frequency division ratio in Pr. 384:
Maximum number of input pulses (pps) = Pr. 384 × 400
Detectable frequency
The detectable frequency changes with the maximum number of input pulses.

5.6 Specifications

Circuit system
Input current
Max. permissible number of pulses
Input pulse specifications
Response delay
Pr. 386
>
2 × 16.6ms × Pr. 384 × 400
56
Open collector system
10mA
100kpps
0f to 250f (f: variable frequency)
16.6ms