REMARKS
If "E.ECT" (no encoder signal) is displayed causing the inverter to trip when the orient signal (X22) is ON, check for
an open cable of the Z phase of the encoder.
(2) Pr. 357 "orientation in-position zone"(factory
setting:11)
• The positioning width for orientation stop can be set.
• The factory setting of Pr. 357 is "11". To change the ∆θ
value, finely adjust with 10 increments, and make fine
adjustment.
• If the position detection value from the encoder enters
∆θ during orientation stop, the orientation complete
signal (ORA) will be output.
CAUTION
This setting is used to judge the ON/OFF of the orientation complete signal, and does not
determine the orientation stop precision.
ORIENTATION CONTROL AT A MACHINE END— V500
Example of operation
Set point
∆θ
∆θ
∆θ =
Pr.851 number of encoder pulses × 4
75
360°
× Pr.357