4.1 Wiring Example

NFB
Power supply
Forward rotation
Reverse rotation
Frequency setting
potentiometer
*1 When the motor with encoder used is other than the standard motor with encoder (SF-JR), the pin numbers are
different.
To reduce radiation noise, connect the shielded wires of the encoder cables to the cable earth (ground) pin.
*2 When encoder feedback control is used with orientation control, the encoder and 5V power supply may be shared
between these controls.
*3 Couple the encoder in line with the motor with a speed ratio of 1 to 1 without any mechanical looseness.
*4 Keep the accessory jumpers connected.
However, when the same encoder is shared between the FR-A5AP and the other unit (e.g. NC) which is connected
with a terminal resistor, the built-in terminal resistors are not required and should be removed. (Terminal resistors;
100Ω)
Standard motor
with encoder (SF-JR)
Inverter
U
R (L1)
V
S (L2)
W
T (L3)
FR-A5AP
STF
C
PA1
STR
R
PA2
SD
(*4)
PAR
A
PB1
N
PB2
10
(*4)
PBR
H
5V
2
K
SG
5
E
(*1)
5V
5VDC
0
power supply
ENCODER FEEDBACK CONTROL—A500(L)
(*3)
1000pF
+
IM
-
1000pF
1000pF
+
-
1000pF
encoder
(*2)
33
1kΩ
100Ω
1kΩ
100Ω
100Ω
1kΩ
100Ω
100Ω
100Ω
1kΩ
1µF
PA1
PAR
PA2
Jumpers
PB1
PBR
PB2
5V
SG

Advertisement