Mitsubishi Electric FR-A5AP Instruction Manual page 53

Transistorized inverter
Table of Contents

Advertisement

ENCODER FEEDBACK CONTROL—A500(L)
! Torque Characteristic of the Standard Motor with encoder (Example: SF-JR Standard Motor with encoder
(4 poles))
[
Cyclic operation mode setting
When the inverter used has a capacity one rank higher
than that of the motor and the rated voltage is input
Short-duration maximum torque
150
1.5kW or less
50%ED
100
50
33
0
*1 The maximum speed is 1) 0.4kW to 7.5kW: 3600r/min, 2) 11kW to 30kW: 3000r/min, 3) 37kW to 55kW: 1950r/min.
*2 Continuous, repetitive operation of 50%ED can be performed in cycle time of 10 minutes. Note that the maximum
continuous operation time is 5 minutes.
*3 Use the constant-torque motor (SF-JRCA with encoder) when 50%ED with 100% torque is required for 2.2kW or
more at 900r/min or less.
*4 Use the constant-torque motor (SF-JRCA with encoder) when continuous 100% torque is required for 2.2kW or
more at 600r/min or less.
CAUTION
1. To provide 150% torque from 0Hz to the rated speed of the motor the inverter should be one
rank higher than the motor.
2. Cyclic operation when the inverter and motor have the same capacity is possible but typically
only 50% torque can be produced.
3. Continuous operation when the inverter capacity is one rank higher than the motor will produce
the same results as when the inverter and motor capacity are the same (as shown above).
With Reference to 1800r/min (60Hz) Torque
(*2)
2.2kW or more
50%ED (*3)
(*1)
900
1800
3600
Speed [r/min]
] [
Continuous operation mode setting
When the inverter used has the same capacity as
that of the motor and the rated voltage is input
150
1.5kW or less
Continuous
operation torque
100
82
40
33
0
180
46
Short-duration maximum torque
2.2kW or more
Continuous
operation torque
(*4)
600
1500
1800
3600
(*1)
Speed [r/min]
]