CHAPTER 5: SETTINGS
Operand type
Operand syntax
INPUTS/OUTPUTS:
Virt Ip 1 On
Virtual inputs
Virt Ip 2 On
Virt Ip 3 On
Virt Ip 64 On
INPUTS/OUTPUTS:
Virt Op 1
Virtual outputs
Virt Op 2
Virt Op 3
Virt Op 96
LED INDICATORS:
LED IN SERVICE
Enhanced and
LED TROUBLE
standard front panels
LED TEST MODE
LED TRIP
LED ALARM
LED PICKUP
LED VOLTAGE
LED CURRENT
LED FREQUENCY
LED OTHER
LED PHASE A
LED PHASE B
LED PHASE C
LED NEUTRAL/GROUND
LED INDICATORS:
LED IN SERVICE
Graphical front panel
LED TROUBLE
LED TEST MODE
LED TRIP
LED ALARM
LED PICKUP
LED VOLTAGE
LED CURRENT
LED FREQUENCY
LED OTHER
LED PHASE A
LED PHASE B
LED PHASE C
LED NEUTRAL/GROUND
LED INDICATORS:
LED TEST IN PROGRESS
LED test
LED INDICATORS:
LED USER 1
User-programmable
LEDs
Enhanced and
standard front panels
LED USER 2 to 48
LED INDICATORS:
EVENT CAUSE LED 1
User-programmable
EVENT CAUSE LED 2 to 9
LEDs
Graphical front panel
D60 LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
Operand description
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
On
Flag is set, logic=1
On
Flag is set, logic=1
On
Flag is set, logic=1
On
Flag is set, logic=1
Asserted when the front panel IN SERVICE LED is on
Asserted when the front panel TROUBLE LED is on
Asserted when the front panel TEST MODE LED is on
Asserted when the front panel TRIP LED is on
Asserted when the front panel ALARM LED is on
Asserted when an element picks up and to turn PICKUP LED on
Asserted when a voltage element involved and to turn VOLTAGE LED on
Asserted when a current element involved and to turn CURRENT LED on
Asserted when a frequency element involved and to turn FREQUENCY LED on
Asserted when a composite element involved and to turn OTHER LED on
Asserted when phase A involved and to turn PHASE A LED on
Asserted when phase B involved and to turn PHASE B LED on
Asserted when phase C involved and to turn PHASE C LED on
Asserted when a neutral or ground element involved and to turn NEUTRAL/
GROUND LED on
Asserted when the front panel IN SERVICE LED is on
Asserted when the front panel TROUBLE LED is on
Asserted when the front panel TEST MODE LED is on
Asserted when the front panel TRIP LED is on
Asserted when the front panel ALARM LED is on
Asserted when an element picks up and to turn Event Cause LED 1 on by
default
Asserted when a voltage element involved and to turn Event Cause LED 2 on
by default
Asserted when a current element involved and to turn Event Cause LED 3 on
by default
Asserted when a frequency element involved and to turn Event Cause LED 4
on by default
Asserted when a composite element involved and to turn Event Cause LED 5
on by default
Asserted when phase A involved and to turn Event Cause LED 6 on by default
Asserted when phase B involved and to turn Event Cause LED 7 on by default
Asserted when phase C involved and to turn Event Cause LED 8 on by default
Asserted when a neutral or ground element involved and to turn Event Cause
LED 9 on by default
An LED test has been initiated and has not finished
Asserted when user-programmable LED 1 is on
The operand above is available for user-programmable LEDs 2 through 48
Asserted when event cause LED 1 is on
Same operand as EVENT CAUSE LED 1