Changing Camera Serial Number

Note:
This program is used to update the cameras serial number when the
CCD is changed. Since the CCD contains the EEPROM, the serial
number would be lost when the CCD is changed (either no serial number
will be present, or a previously assigned number which was used by a
different camera may be in the new CCD EEPROM.

Required Test Equipment and Tools

• Mac Centris 650 computer or equivalent
• PDC 2000 Switching Power Supply
• Camera SCSI Cable
• Camera Test Fixture (Nest)
Equipment Setup (Figure 3-9)
1. Place the camera onto the test fixture (camera nest).
2. Connect the camera SCSI cable from the host computer SCSI connector to the camera
SCSI connector.
3. Connect the switching power supply cable to the camera's external power connector.
4. If applicable, set the camera's SCSI ID to 4.
5. If applicable, replace camera lens with an 11mm lens.
Note:
11mm lens is standard. Some camera's come in for repair with the
optional 17mm lens attached.
For testing purposes the standard 11mm lens must be used.
6. Turn on the test equipment as follows:
• Mac Centris 650 computer On/Off (0/1) switch to On (1).
• Turn on the camera.