Polaroid PDC2000 Repair Manual page 52

Hide thumbs Also See for PDC2000:
Table of Contents

Advertisement

PDC 2000/3000 Repair Manual
9. If applicable, replace camera lens with an 11mm lens.
Note:
11mm lens is standard. Some camera's come in for repair with the optional
17mm lens attached. For testing purposes the standard 11mm lens must
be used.
10. Turn on the test equipment as follows:
• Mac Centris 650 Computer On/Off (0/1) switch to On (1).
• Turn on the camera.
Camera Power
Mac Centris 650
Computer
Diorama
Bench
Supply
Camera
SCSI Cable
Figure 3-12. Dimestore setup
Checker/Resolution
Target
Diorama
Camera Nest
Focus Gear
Focus Gear
Pin
53
Testing & Adjustment
PDC 2000/3000