Clean Sweep; Required Test Equipment And Tools; Equipment Setup - Polaroid PDC2000 Repair Manual

Hide thumbs Also See for PDC2000:
Table of Contents

Advertisement

PDC 2000/3000 Repair Manual

Clean Sweep

Note:
This program is used to remove all pictures from the hard drive of dealer return
cameras .

Required Test Equipment and Tools

• Power Computing Power PC or equivalent
• PDC 2000 Switching Power Supply
• Camera SCSI Cable
• Diorama Test Bench
• PDC Diorama Camera Test Fixture (Nest)
• Checker/Resolution Target
Equipment Setup (Figure 3-14)
1. Place the camera onto the PDC Diorama Camera Test Fixture (Nest).
2. Flip up the checker/resolution target. Camera should be aimed at checker/resolution
target.
3. Connect the camera SCSI cable from the host computer SCSI connector to the camera
SCSI connector.
4. Connect the switching power supply cable to the camera's external power connector.
5. If applicable, set the camera's SCSI ID to 4.
6. If applicable, replace camera lens with an 11mm lens.
Note:
11mm lens is standard. Some camera's come in for repair with the
optional 17mm lens attached. For testing purposes the standard 11mm lens
must be used.
7. Turn on the test equipment as follows:
• Power Computiing PC On/Off (0/1) switch to On (1).
• Turn on the camera.
60
Testing & Adjustment

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdc-2000/40Pdc-2000/tPdc3000Pdc-2000/60

Table of Contents