Performing An Issu For A Single-Mpu Device - HP 10500 Series Configuration Manual

Hide thumbs Also See for 10500 Series:
Table of Contents

Advertisement

Step
5.
Perform an
active/standby
switchover and upgrade
the service cards and
switching fabric cards.
6.
(Optional.) Accept the
upgrade and delete the
automatic-rollback timer.
7.
Complete the ISSU
process or roll back to
the original software
configuration.
To perform an ISSU for an incompatible version, execute one of the following commands in user view:
Step
1.
Upgrade the
standby MPU and
configure the
upgrade images as
the main startup
software images for
the standby MPU.
2.
Complete the ISSU
process or roll back
to the original
software
configuration.

Performing an ISSU for a single-MPU device

Before upgrade, use the display version comp-matrix file { boot filename | system filename | feature
filename&<1-30> } * or the display version comp-matrix file ipe ipe-filename command to display the
compatibility between the new and old images and the upgrade methods to be used. If a new image is
Command
issu run switchover
issu accept
To upgrade the original active
MPU and complete the ISSU:
issu commit slot slot-number
To roll back to the original
software configuration:
issu rollback
Commands
Method 1:
issu load file { boot filename | system
filename | feature filename&<1-30> } *
slot slot-number
Method 2:
issu load file ipe ipe-filename slot
slot-number
To complete the ISSU process, perform
an active/standby switchover to upgrade
all cards except for the upgraded MPU:
issu run switchover
To roll back to the original software
configuration:
issu rollback
122
Remarks
N/A
N/A
Specify the slot number of the original
active MPU for the slot slot-number
option.
After the issu commit command is
completed, the ISSU process ends and
the ISSU status changes to Init.
During this ISSU process, you can use the
issu rollback command to roll back to the
original software configuration. For more
information about rollback, see
Fundamentals Command Reference.
Remarks
Specify the slot number of the
standby MPU for the slot
slot-number option.
After the issu run switchover
command is completed, the ISSU
process ends and the ISSU status
changes to Init.
During this ISSU process, automatic
rollback is not supported, but you
can use the issu rollback command
to manually roll back to the original
software configuration. For more
information about rollback, see
Fundamentals Command
Reference.