Advertisement

flash:/boot-r2110.bin
flash:/system-r2110.bin
flash:/feature1-r2110.bin
# Identify the ISSU method and possible impacts of the upgrade on the device.
<Sysname> display version comp-matrix file feature flash:/feature1-r2111.bin
Feature image: flash:/feature1-r2111.bin
Version:
V700R001B45D002
Version Compatibility List:
V700R001B45D001
V700R001B45D002
Version Dependency System List:
V700R001B45D001
V700R001B45D002
Slot
0
1
Influenced service according to following table on slot 0:
flash:/feature1-r2111.bin
feature1
Influenced service according to following table on slot 1:
flash:/feature1-r2111.bin
feature1
The output shows that an incremental upgrade is recommended and the feature1 feature module will be
rebooted during the upgrade process.
# Upgrade feature1 on the standby MPU.
<Sysname> issu load file feature flash:/feature1-r2111.bin slot 1
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version
Release 2110
Slot
1
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Perform an active/standby switchover.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version
Release 2110
Slot
0
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Upgrade the feature on the original active MPU.
Upgrade Way
Service Upgrade
Service Upgrade
New Version
Release 2111
Upgrade Way
Service Upgrade
New Version
Release 2111
Switchover Way
Active standby process switchover