When the temperature of a card reaches the shutdown threshold, the device logs the event, notifies users
by repeatedly sending log messages, and shuts down the card. The shutdown threshold is not
configurable.
To configure the temperature alarm thresholds:
Step
1.
Enter system view.
2.
Configure the temperature
alarm thresholds.
Table 16 Default temperature alarm thresholds
Card type
MPU
A-type
LSU1FAB04A
switching
fabric
LSU1FAB08A
module
LSU1FAB04B
B-type
switching
LSU1FAB08B
fabric
module
LSU1FAB12B
Command
system-view
In standalone mode:
temperature-limit slot slot-number
{ hotspot | inflow } sensor-number
lowlimit warninglimit [ alarmlimit ]
In IRF mode:
temperature-limit chassis
chassis-number { slot slot-number }
{ hotspot | inflow } sensor-number
lowlimit warninglimit [ alarmlimit ]
Low-temperature
Sensor
threshold
Inflow 1
0°C (32°F)
Hotspot 1
0°C (32°F)
Hotspot 1
0°C (32°F)
Hotspot 1
0°C (32°F)
Hotspot 2
0°C (32°F)
Hotspot 1
0°C (32°F)
Hotspot 2
Hotspot 3
0°C (32°F)
Hotspot 1
0°C (32°F)
Hotspot 2
Hotspot 3
0°C (32°F)
Hotspot 4
172
Remarks
N/A
For the default settings, see
16.
The high-temperature alarming
threshold must be higher than the
high-temperature warning
threshold. The high-temperature
warning threshold must be higher
than the low-temperature
threshold.
Warning
Alarming
threshold
threshold
48°C
60°C
(118.4°F)
(140°F)
80°C
95°C
(176°F)
(203°F)
75°C
90°C
(167°F)
(194°F)
68°C
80°C
(154.4°F)
(176°F)
88°C
100°C
(190.4°F)
(212°F)
68°C
80°C
(154.4°F)
(176°F)
88°C
100°C
(190.4°F)
(212°F)
68°C
80°C
(154.4°F)
(176°F)
88°C
100°C
(190.4°F)
(212°F)
Table
Shutdown
threshold
N/A
N/A
N/A
N/A
110°C
(230°F)
N/A
110°C
(230°F)
N/A
110°C
(230°F)

Hide quick links: