HP 10500 Series Configuration Manual page 143

Hide thumbs Also See for 10500 Series:
Table of Contents

Advertisement

flash:/feature1-r2111.bin
feature1
Influenced service according to following table on slot 1:
flash:/feature1-r2111.bin
feature1
The output shows that an incremental upgrade is recommended and the feature1 feature module will be
rebooted during the upgrade process.
# Upgrade feature1 on the standby MPU.
<Sysname> issu load file feature flash:/feature1-r2111.bin slot 1
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version
Release 2110
Slot
1
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Perform an active/standby switchover.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version
Release 2110
Slot
0
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Display active software images.
<Sysname> display install active
Active packages on slot 0:
flash:/boot-r2110.bin
flash:/system-r2110.bin
flash:/feature1-r2110.bin
Active packages on slot 1:
flash:/boot-r2110.bin
flash:/system-r2110.bin
flash:/feature1-r2111.bin
# Roll back feature1 to R21 10.
<Sysname> issu rollback
This command will quit the ISSU process and roll back to the previous version. Continue?
[Y/N]:Y
New Version
Release 2111
Upgrade Way
Service Upgrade
New Version
Release 2111
Switchover Way
Active standby process switchover
135