8.3.2.2

Drive settings

NOTE
8-10
www.aotewell.com
With menu File
New
parameterization (see Fig. 8-5). The system creates a download file
(*.dnl), in which the drive characteristic data (type, software version) are
stored. You can create the download file on the basis of an empty
parameter set or the factory setting.
Fig. 8-5

Creating a new drive

Once you have created a drive, you can start it again with the menu
function File
Open for parameterization by opening the download
file. The last four drives can be opened via "Parameter sets last dealt
with".
When you create a new drive, the window "Properties - Drive" (Fig. 8-6)
opens. Here you must enter the following data:
♦ In dropdown list box "Device type", select the type of device (e.g.
MASTERDRIVES VC(Plus)). You can only select the devices
stored.
♦ In dropdown list box "Software version", you can select the software
version of the device. You can generate databases for (new)
software versions that are not listed when you start online
parameterization.
♦ You must only specify the bus address of the drive during online
operation (switchover with button Online/Offline)
The specified bus address must be the same as that of the
parameterized SST bus address in SIMOVERT MASTERDRIVES
(P700).