Setting The Interface; Online Settings; Interface Configuration - Siemens 6SE7011-5EP60 Operating Instructions Manual

Simovert masterdrives vector control series frequency converter (ac-ac) compact plus type
Table of Contents

Advertisement

05.2003
8.3.2.1

Setting the interface

NOTE
Siemens AG
6SE7087-6JP60
SIMOVERT MASTERDRIVES
www.aotewell.com
You can configure the interface with menu Tools
Fig. 8-3

Online settings

The following settings (Fig. 8-4) are possible:
♦ Tab card "Bus Type", options
USS (operation via serial interface)
Profibus DP (only if DriveMonitor is operated under Drive ES).
♦ Tab card "Interface"
You can enter the required COM interface of the PC (COM1 to
COM4) and the required baudrate here.
Set the baudrate to the baudrate parameterized in SIMOVERT
MASTERDRIVES (P701) (factory setting 9600 baud).
Further settings: operating mode of the bus in RS485 operation;
setting according to the description of the interface converter
RS232/RS485.
♦ Tab card "Extended"
Request retries and Response timeout; here you can increase the
values already set if communication errors occur frequently.
Fig. 8-4

Interface configuration

Operating Instructions
sales@aotewell.com
Industry Automation
Parameterization
ONLINE Settings.
8-9