Parameter Input Via The Op1S; General - Siemens 6SE7011-5EP60 Operating Instructions Manual

Simovert masterdrives vector control series frequency converter (ac-ac) compact plus type
Table of Contents

Advertisement

05.2003
8.5

Parameter input via the OP1S

8.5.1

General

Order numbers
Siemens AG
6SE7087-6JP60
SIMOVERT MASTERDRIVES
www.aotewell.com
The operator control panel (OP1S) is an optional input/output device
which can be used for parameterizing and starting up the units. Plain-
text displays greatly facilitate parameterization.
The OP1S has a non-volatile memory and can permanently store
complete sets of parameters. It can therefore be used for archiving sets
of parameters. The parameter sets must be read out (upread) from the
units first. Stored parameter sets can also be transferred (downloaded)
to other units.
The OP1S and the unit to be operated communicate with each other via
a serial interface (RS485) using the USS protocol. During
communication, the OP1S assumes the function of the master whereas
the connected units function as slaves.
The OP1S can be operated at baud rates of 9.6 kBd and 19.2 kBd, and
is capable of communicating with up to 32 slaves (addresses 0 to 31). It
can therefore be used both in a point-to-point link (e.g. during initial
parameterization) and within a bus configuration.
The plain-text displays can be shown in one of five different languages
(German, English, Spanish, French, Italian). The language is chosen by
selecting the relevant parameter for the slave in question.
Components
OP1S
Connecting cable 3 m
Connecting cable 5 m
Adapter for installation in cabinet door incl. 5 m cable
Operating Instructions
sales@aotewell.com
Industry Automation
Parameterization
Order Number
6SE7090-0XX84-2FK0
6SX7010-0AB03
6SX7010-0AB05
6SX7010-0AA00
8-21
+86-755-8660-6182

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents