Quick Start Guide
Remote electronics
If you order one of the remote electronics options (options R10, R20, R30, R33,
R50, or RXX), the flowmeter assembly ships in two parts:
The meter body with an adapter installed in the support tube and an
interconnecting coaxial cable attached to it.
The electronics housing installed on a mounting bracket.
If you order the armored remote electronics options, follow the same instructions
as for the standard remote cable connection with the exception that the cable
may not need to be run through conduit. Armored includes the glands.
Mounting
Mount the meter body in the process flow line as described earlier in this section.
Mount the bracket and electronics housing in the desired location. The housing
can be repositioned on the bracket to facilitate field wiring and conduit routing.
Cable connections
Refer to
Figure 9
coaxial cable to the electronics housing.
Figure 9. Remote Electronics Installation
C
D
E
F
G
1
A.
/
NPT conduit adapter or cable gland
2
(supplied by customer)
B. Coaxial cable
C. Meter adapter
D. Union
E. Washer
F. Nut
G. Sensor cable nut
H. Support tube
8
and the instructions on
A
B
H
I
page 9
to connect the loose end of the
P
O
N
M
I. Meter body
J. Electronics housing
K. Coaxial cable nut
L. Conduit adapter
(optional-supplied by customer)
M. Housing adapter screws
N. Housing adapter
O. Housing base screw
P. Ground connection
April 2016