Canadian Standards Association (CSA)
E6 Explosion-Proof for Class I, Division 1, Groups B, C, and D;
Dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G
Class I, Zone 1, AEx d [ia] IIC T6 Gb (-50 °C ≤ Ta ≤ 70 °C)
Factory Sealed; Single Seal; Enclosure Type 4X
Install per drawing 08800-0112
I6 Intrinsically safe for use in Class I, II, III Division 1, Groups A, B, C, D, E, F, G;
Non-incendive for Class I, Division 2, Groups A, B, C and D
Class I, Zone 0, AEx ia IIC T4 Ga
Temperature Code T4 (-50 °C  Ta  70 °C) 4-20 mA HART
Temperature Code T4 (-50 °C  Ta  60 °C) Fieldbus
Single Seal; Enclosure Type 4X
Install per drawing 08800-0112
IF FISCO for Class I, Division 1, Groups A, B, C, and D
FNICO for Class I Division 2, Groups A, B, C, and D
Class I, Zone 0, AEx ia IIC T4 Ga
Temperature Code T4 (-50 °C  Ta  60 °C)
Install per drawing 08800-0112
Single Seal; Enclosure Type 4X
Combined Canadian Certifications (CSA)
K6 E6 and I6 Combination
Combined North America Certifications (FM and CSA)
KB E5, I5, E6, and I6 Combination
5.2 European Certifications
ATEX Intrinsic Safety
EN 60079-0: 2012 + A11: 2013
EN 60079-11: 2012
I1 Certification No. Baseefa05ATEX0084X
ATEX Marking
II 1 G Ex ia IIC T4 Ga (-60 °C  Ta  70 °C) 4-20 mA HART
II 1 G Ex ia IIC T4 Ga (-60 °C  Ta  60 °C) Fieldbus
2460
4-20 mA HART
entity parameters
U
= 30 VDC
i
(1)
I
= 185 mA
i
(1)
P
= 1.0 W
i
= 0 F
C
i
L
= 0.97mH
i
1.Total for transmitter.
22
Fieldbus entity
parameters
U
= 30 VDC
i
(1)
I
= 300 mA
i
(1)
P
= 1.3 W
i
= 0 F
C
i
< 10 H
L
i
FISCO input
parameters
U
= 17.5 VDC
i
(1)
I
= 380 mA
i
(1)
P
= 5.32 W
i
= 0 F
C
i
< 10 H
L
i