Configuring The Power Supply Mode - Cisco MDS 9000 Series Configuration Manual

Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

Configuring the Power Supply Mode

Configuring the Power Supply Mode
You can configure power supply modes.
SUMMARY STEPS
1. configure terminal
2. power redundancy-mode {combined | insrc-redundant | ps-redundant |redundant}
3. (Optional) show environment power
4. (Optional) copy running-config startup-config
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide
148
Table 21: Combined Mode Power Supply Scenarios
Scenario
Power
Current Mode
Supply 1
(W)
1
2500
combined
2500
N/A
2
2500
combined
2500
N/A
3
2500
combined
2500
N/A
Current Usage
Power
(W)
Supply 2 (W)
2000
1800
2000
1800
2000
2200
2000
2200
3000
1800
3000
1800
Managing System Hardware
New
New
Action
Mode
Capacity
Taken by
Switch
N/A
3600
This is
the
existing
configuration.
redundant
2500
Power
supply 2
is shut
down.
N/A
4400
This is
the
existing
configuration
redundant
2200
The new
capacity
is
changed.
N/A
3600
This is
the
existing
configuration
redundant
N/A
Rejected,
so the
mode
reverts to
combined
mode.
OL-29291-02

Advertisement

Table of Contents
loading