Chapter 3
Configuring Catalyst 2955 Switch Alarms

Configuring the Power Supply Alarm

This section describes how to configure the power supply alarm on your switch. It contains this
configuration information:

Setting the Power Mode

The Catalyst 2955 switch has two DC power inputs. By default, the system operates in the single power
mode. You can use the power-supply dual global configuration command to set the dual mode
operation. In dual-power mode, a second power supply gives power to the switch if the primary power
supply fails.
Beginning in privileged EXEC mode, follow these steps to set the switch to dual power mode operation:
Command
Step 1
configure terminal
Step 2
power-supply dual
Step 3
end
Step 4
show alarm settings
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Use the no power-supply dual command to disable this alarm by setting the switch back to single power
mode operation.

Setting the Power Supply Alarm Options

Use the alarm facility power-supply global configuration command to associate the power supply
alarm to a relay. You can also configure all alarms and traps associated with the power supply alarm to
be sent to syslog and the SNMP server.
Beginning in privileged EXEC mode, follow these steps to associate the power supply alarm to a relay:
Command
Step 1
configure terminal
Step 2
alarm facility power-supply relay
{major | minor}
Step 3
alarm facility power-supply notifies Configure sending power supply alarm traps to an SNMP server.
Step 4
alarm facility power-supply syslog
Step 5
end
Step 6
show alarm settings
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.
78-11380-12
Setting the Power Mode, page 3-5
Setting the Power Supply Alarm Options, page 3-5
Purpose
Enter global configuration mode.
Set the system to dual mode operation.
Return to privileged EXEC mode.
Verify the configuration.
Purpose
Enter global configuration mode.
Associate the power supply alarm to the major or minor relay.
Configure sending power supply alarm traps to a syslog server.
Return to privileged EXEC mode.
Verify the configuration.
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
Configuring Catalyst 2955 Switch Alarms
3-5