Table 28: LEDs for the Cisco MDS 9000 Family Fibre Channel Switching Modules
LED
Status
Speed
OL-29291-02
Status
Green
Red
Orange
On
Off
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide
Identifying Module LEDs
Description
All diagnostics pass. The module
is operational (normal initialization
sequence).
The module is booting or running
diagnostics (normal initialization
sequence).
or
The inlet air temperature of the
system has exceeded the maximum
system operating temperature limit
(a minor environmental warning).
To ensure maximum product life,
you should immediately correct the
environmental temperature and
restore the system to normal
operation.
The diagnostic test failed. The
module is not operational because
a fault occurred during the
initialization sequence.
or
The inlet air temperature of the
system has exceeded the safe
operating temperature limits of the
card (a major environmental
warning). The card has been shut
down to prevent permanent
damage.
2-Gbps mode.
1-Gbps mode.