Cisco MDS 9000 Series Configuration Manual page 193

Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

Managing Modules
LED
System
Note
Active
Pwr Mgmt
MGMT 10/100 Ethernet Link LED
MGMT 10/100 Ethernet Activity
LED
Compact Flash
OL-29291-02
Status
Green
The System and Pwr
Mgmt LEDs on a
Orange
redundant supervisor
module are synchronized
to the active supervisor
module.
Red
Green
Orange
1
Green
Orange
Green
Off
Green
Off
Green
Off
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide
Identifying Module LEDs
Description
All chassis environmental monitors
are reporting OK.
The power supply has failed or the
power supply fan has failed.
or
Incompatible power supplies are
installed.
or
The redundant clock has failed.
The temperature of the supervisor
module major threshold has been
exceeded.
The supervisor module is
operational and active.
The supervisor module is in
standby mode.
Sufficient power is available for all
modules.
Sufficient power is not available
for all modules.
Link is up.
No link.
Traffic is flowing through port.
No link or no traffic.
The external CompactFlash card is
being accessed.
No activity.
175

Advertisement

Table of Contents
loading

Table of Contents