Arkel ARCODE Quick Installation Manual page 61

Integrated elevator controller for traction lifts
Table of Contents

Advertisement

Available languages

Available languages

Arkel Elektrik Elektronik San. ve Tic. A.Ş.
EPro:
in the process of reading from Eprom or writing to Eprom now
0.00:
SEV key is activated. The elevator is stopping, speed value is 0.00 m/s
LuL :
SEV key is activated. The elevator is moving with brake releasing. The car is at the door-zone and speed
is lower than 0.3 m/s.
StoP:
SEV key is activated. The elevator is moving with brake releasing. The speed is greater than 0.3 m/s.
UpEx(x=9..0)
Enca software is being updated. "x" number shows the remaining time of update. It counts from 9 to 0.
When it reaches 0, update process is ended.
u36:
the car runs away from the floor which detects fire in U36 function mode.
Parc:
It is going to park floor.
The elevator is in "Out of Service" mode with "OOS" input.
noSr:
In order to clear the permanent error, the following 2 steps should be performed.
On AREM,
1) Tools  System Tools  Clear Permanent Error
2) Tools  System Tools  Reset System
ARKEL
61
www.arkel.com.tr
Appendix-2
Appendix-3
ARCODE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents