Installation Of Magnets For Sml1-Sml2 Door Zone Sensors - Arkel ARCODE Quick Installation Manual

Integrated elevator controller for traction lifts
Table of Contents

Advertisement

Available languages

Available languages

Arkel Elektrik Elektronik San. ve Tic. A.Ş.
 Make the installation of bar magnets for SML1&SML2 door zone switches. The cables of magnetic switches must be
connected
ML1-ML0-1000 and ML2-ML0-1000 terminals on IBC board respectively.
CAR
FLOOR LEVEL
Figure-14: Installation of magnets for SML1-SML2 door zone sensors
If motor has brake mikroswitch(es) connect it to BRM and BRM2 inputs.(see figure 4-2). And select "on"
"Mechanical brake monitoring" and "Mechanical brake-2 monitoring".
Also "Operation mode" must be selected "Normal Operation" which is located under "Basic settings".
ARKEL
Move the car to the end of floors.
Car threshold must be exactly at the floor level.
15cm
Install the bar magnet opposite to the zone magnetic switches. The middle of
the ribbon magnet must be on a level with the middle of the magnetic
switches.
15cm
The distance between magnetic switches and magnet must be 1-2 cm.
30 cm bar magnets must be fixed with screw or glue.
Repeat this installing operation at all floors.