Picture Memory Settings Of Lcd; Lcd Update Screen; Lcd Type Selection; Step-8: Other Settings - Arkel ARCODE Quick Installation Manual

Integrated elevator controller for traction lifts
Table of Contents

Advertisement

Available languages

Available languages

Arkel Elektrik Elektronik San. ve Tic. A.Ş.

Step-8: Other Settings

Picture Memory Settings of LCD

The software must be updated like explained Appendix-1 when first time a LCD is connected CANBus line. The software
update should be done after all LCDs are connected CANBus line. The Picture memory is empty when first time an LCD
is connected CANBus line.
Figure-19a: LCD Update Screen
Figure-19b: LCD type selection
ARKEL
The AREM must be connected which is located
same LCD CANBus line. If you want to update
LCD of COP the AREM must be connected to
COP. If LCDs of landings are wanted to update
this time the AREM must be connected shaft
CANBus line. Other wise ARCODE can not find
correct LCDs.
To update Picture memory of LCD, select "LCD
update screen" and press Enter button.
Updated LCD type is selected and pressed Enter
button.
To select message right/left arrows are used. To
select Picture for message up/down arrows are
used.
All changes are saved in memory of LCD.