Steps-5: Preparations for Normal Operation

Make all the other mechanical installations of elevator system and make the inspection box wiring, pit box
wiring and safety circuit wirings.
Make the installation of round magnets for SKSR1 bottom limit switch (bottom correction sensor). The cables of
SKSR1 magnetic switch must be connected 100 and 817 terminals in IBC board. Round magnets of bottom limit
switch must be put as shown Figure-12. The needed distance for magnets is shown on AREM screen When
parameter "Shaft Learning" is selected.
The deceleration distance is
Shown on AREM screen
Figure-12: Installation of magnets for SKSR1 bottom
correction sensor
Make the installation of round magnets for SKSR2 top limit switch (top correction sensor). The cables of
magnetic switch must be connected 100 and 818 terminals in IBC board. Round magnets of top limit switch
must be put as shown Figure-13.
The deceleration distance
is Shown on AREM screen
Figure-13: Installation of magnets for SKSR2
top
ARKEL
Black side
Red side
BOTTOM FLOOR LEVEL
TOP FLOOR LEVEL
47
Move the car to the bottom floor. Car must be exactly at
the floor level
Install the round magnet with red color side above the
SKSR1 magnetic switch as deceleration distance. It
means it must be switched on when down deceleration
signal for bottom floor is activated.
Install the round magnet with black color side a little
above the red color magnet. It means it must be switched
off when the car is out of the bottom limit zone. The
distance between magnetic switch and magnets must be 1-
2 cm.
Move the car to the top floor. Car must be exactly at the
floor level.
Install the round magnet with red color side below the
SKSR2 magnetic switch as deceleration distance. It
means it must be switched on when up deceleration signal
for top floor is activated.
Install the round magnet with black color side a little
below the red color magnet. It means it must be switched
off when the car is out of the top limit zone. The distance
between magnetic switch and magnets must be 1-2 cm.