81-Group identity conflict error:

error. "P0086 group identity" should be chosen for all elevators in a right way.
- Give a different ID for each elevators in the group by checking this parameter.
82-Number of stops of all lifts in the group must be same:
entered different for the elevators in the group, it gives this error.

83-APRE could not be unlocked:

monitoring input (APRI) should be zero within 3 seconds. Otherwise, it gives this error.
Note: This is a permanent error. In order to get rid of the permanent error case, look at Appendix-3.

84-APRE could not be locked:

Apre triggering output(APRO) is zero, the apre monitoring input (APRI) should be 1 within the time "P0804 speed
governor locking time" parameter. Otherwise, it gives this error.
Note: This is a permanent error. In order to get rid of the permanent error case, look at Appendix-3.
85-Encoder reference error:
angle correction by reference signal exceeded 120 degrees (magnetic)
- Check encoder connections.
- Check encoder-motor mechanical coupling. Encoder wheel might be slipping.
- Check if Z-channel reference signal is correct

86-UCM detected:

If door is bridged and 140 or 130 is "0" and if one of ML1 or ML2 is "0", it gives this error.
Note: This is a permanent error. In order to get rid of the permanent error case, look at Appendix-3.
87-Out of re-level zone:
signals" , when the car waits at floor, if 141 and 142 turn to zero, it gives this error.
If "P0075 relevelling function"parameter is chosen as "with Liftsense", when the car waits at floor, if the value which is
read from Liftsense should be in the interval of +7 cm ve -7 cm. Otherwise it gives this error.
88-Overspeed on relevelling:
overspeed error limit on relevelling" parameter, it gives this error.
89-Could not hold car on starting:
this error.
- Adjust Anti-rollback PID gains. (KP and KD parameters)
90-Overspeed on pre-opening:
entered "P0813 overspeed error limit on pre-opening" parameter, it gives this error.
93-Maintenance time exceeded:
parameter, controller raises error. The system goes out of service until the time parameter is taken to a future date-time.
In order to enable "P1006" parameter, firstly "P1005" maintenance time control parameter should be set as "On".
94-Car light fuse is blown:
error.
ARKEL
If there is a conflict between the elevator identities in the group, it gives this
If "P0788 Apre monitoring" parameter is ON, after brakes are opened, the apre
If "P0788 Apre monitoring" parameter is ON, main contactor output(RP) and
"(P0868) Encoder coupling type" is set to "Indirect incremental encoder" and the
If "P0075 relevelling function" parameter is chosen as "Relevel using 141 and 142
If the speed on relevelling exceeds over the value which is entered "P0814
While starting to move, if the rotor rotates more than quarter-turn, it gives
While the door is bridged, if the speed of the car exceeds over the value which is
When system time passes the date-time entered in maintenance time "P1006"
If 3-phases are OK in Arcode, but there is no voltage value(220V) on IBC, it gives this