95-Manual rescue (SEV key):

error occurs.

96-UPS failed on test:

- Check the batteries.
Note: This is a permanent error. In order to get rid of the permanent error case, look at Appendix-3.

97-Direction change limit reached:

direction change counter has exceeded this value.
- This function is usually used to limit the usage of plastic ropes according to their lifetime. After changing the ropes,
set (P0964) to the next desired limit value.
Note: This is a permanent error. In order to get rid of the permanent error case, look at Appendix-3.

98- One of critical devices is offline:

controller raises error. (Triggering of this error may take about 20 seconds) For ex: Photocell (FSLA) input is assigned to
one of the programmable inputs of IBC board, and if there is a problem about the communication with IBC and main
controller, this error is triggered in normal operation. The critical programmable inputs are shown with red color in the
programable input list.
-This error is about EN81-20 norms. Not to receive this error during installation, you should set the "Operation mode"
parameter as "Installation mode".
ARKEL
If "P0810 Acceptance test tools" parameter is OFF and "MEM" signal is ON, this
If UPS test couldn't be performed, it gives this error.
"(P0964) Direction change count limit" is set to a non-zero value and the
During normal operation, if connection with a critical device is lost, the
70