Disassembly and Assembly
Interlock Switch Removal
1. Open the top cover.
cartridge to protect it from light or place it in a dark area.
2. Remove the control panel. (Refer to page 3-10.)
3. Remove the paper cover
4. Remove the right cover. (Refer to pages 3-11 and 3-12.)
5. Remove the power supply unit. (Refer to page 3-15.)
6
Remove 2 CC (M3 x 16) screws for the interlock switch, and remove
interlock switch.
Figure 3-12. Removing the Interlock Switch
3-16
Remove the imaging cartridge. Cover the imaging
EPSON ActionLaser 1600 Service Manual
the