Troubleshooting
Cause
Connector for paper
take-up solenoid may be
disconnected.
The paper take-up
solenoid coil may be open
or shorted.
Paper take-up sensor flag
position may be incorrect.
Paper take-up roller may
be bad.
Table 5-10. The LCD Displays FEED JAM for Lower Paper Cassette
Cause
The paper take-up
solenoid coil for the lower
paper cassette may be
open or shorted.
5-8
Table 5-9. The LCD Displays FEED JAM
Step
C h e c k p o i n t
1
Is connector disconnected?
2
Disconnect connector CN6
on the PWB-A board and
check coil resistance
between pin 7 and pin 8 on
the disconnected cable side
of the connector using a
multimeter.
Is the resistance
approximately 80 ohms?
If the coil is shorted, check
the solenoid drive circuit
using the procedure below:
1. Set the multimeter for
voltage.
2. Place the (--) terminal of
the multimeter on pin 7
of connector CN6 on the
PWB-A board.
3. Place the (+) terminal of
the multimeter on pin 5
(GND).
With power on, does the
multimeter detect any
current?
3
Is paper take-up sensor flag
position incorrect?
4
Step
C h e c k p o i n t
1
Disconnect connector PJ2
on the lower paper cassette
circuit board and check the
coil resistance between
pins 1 and 2 on the
disconnected cable side of
the connector using a
multimeter. Is the resistance
approximately 220 ohms?
Finding
Yes
No
Yes
No
Finding
No
EPSON ActionLaser 1600 Service Manual
Solution
Connect it.
Replace the paper
take-up solenoid.
Replace the paper
take-up solenoid
and the PWB-A
board.
Reseat the paper
take-up sensor flag.
Replace the paper
take-up roller.
Solution
Replace the paper
take-up solenoid.

Advertisement