Power Supply Unit (Pwb-E) Removal; Interlock Switch Removal; Figure 3-11. Removing The Power Supply Unit; Figure 3-12. Removing The Interlock Switch - Epson ActionLaser 1600 EPL-5600 Service Manual

Table of Contents

Advertisement

3.2.3.2 Power Supply Unit (PWB-E) Removal

1.
Open the top cover. Rerr&ve the imaging cartridge. Cover the imaging cartridge to protect it
from light or place it in a dark area.
2.
Remove the control panel. (Re!%r to Section 3.2.13.) "
3.
Remove the paper cover.
4.
Remove the right cover. (Refer to Section 3.2.2.l.)
5.
Disconnect connectors CN1, CN4, and CN2 on the power supply board (PWB-E) and CN8 on
engine controller board (PWB-A).
6.
Disconnect the connectors for the interlock switch.
7.
Remove 2 CP(0) screws (M3 x 6), and remove the power supply unit.
Figure 3-11. Removing

3.2.3.3 Interlock Switch Removal

to
P
from light or place it in a dark area.
2. Remove the control panel. (Refer to Section 3.2.13.)
3. Remove the paper cover.
4. Remove the right cover. (Refer to Section 3.2.2.1.)
5. Remove the power supply unit. (Refer to Section 3.2.3.2.)
6. Remove
screws (M3 x 16) for the interlock switch, and remove the interlock switch.
2 CC
Figure
Rev. A
PWB-A Board
the Power Supply Unit
CC (M3 X 16)
x
3-12. Removing the Interlock Switch