Power Supply Unit (PWB-E) Removal
1. Open the top cover.
cartridge to protect it from light or place it in a dark area.
2. Remove the control panel. (Refer to page 3-10.)
3. Remove the paper cover
4. Remove the right cover. (Refer to pages 3-11 and 3-12.)
5. Disconnect connectors CN1, CN4, and CN2 on the power supply board
(PWB-E) and CN8 on engine controller board (PWB-A).
6. Disconnect the connectors for the interlock switch
7. Remove 2 CP(0) (M3 x 6) screws, and remove the power supply unit
Figure 3-11. Removing the Power Supply Unit