Opticon assumes no liability for any direct, indirect, consequential or incidental damages arising out of use or inability to use both the hardware and software, even if Opticon has been informed about the possibility of such damages.
1. Abstract This manual provides specifications for the OPL 9712 barcode data collector (hereafter referred to as “data collector”). 2. Overview This scanner uses laser technology. To start a scan, press the trigger switch. Do not allow the scanner to directly touch the surface of a barcode when scanning.
Software can be developed in the C programming language. These development tools are available as accessories. Figure 1: Reading a barcode. 3. Physical Features 3.1. Dimensions W 129 mm x D 44 mm x H 22.3 mm 3.2. Weight 105 grams (with lithium-ion batteries installed). Opticon OPL 9712 Specifications Manual...
Quiet Zone: N/W Ratio: Direct light or specular reflection light from a source should be prevented from entering the acceptance area. 3,000 lx 3,000 lx 50,000 lx 0.25 mm 8-digit Code 39 10 mm 1:2.5 Opticon OPL 9712 Specifications Manual...
Red laser diode 650 ±10 (25° C) 1.0 or less Bi-directional vibration mirror 100 ±20 Scan angle: 54 ±5 Read angle: 44 (Min) 0.15 or more Opticon OPL 9712 Specifications Manual Remarks Remarks Manufactured by Toshiba For BIOS/AP For WORK/DATA Unit scans/s °...
Reso lu t ion 0 .15 Reso lu t ion 0 .25 Reso lu t ion 0 .5 Reso lu t ion 1 .0 Figure 3: The depth of field Opticon OPL 9712 Specifications Manual M in i mu m read ing d is tance...
Page 10
Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully. Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio: 1:2.5 Angle: α = 0°, β = 15°, γ = 0° Curvature: R = ∞ Decode Depth (mm) 60–300 35–210 35–120 35–70 Opticon OPL 9712 Specifications Manual Digit...
Opticon OPL 9712 Specifications Manual Skew Angle and Dead Zone 8.3.2. Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) (Depth of field: Within 90 mm from the minimum scannable distance).
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance: Angle: The scanning range will vary according to the depth of field. Figure 7: Curvature 90 mm from the edge of the data collector Skew Angle β = +15° Opticon OPL 9712 Specifications Manual...
2. The communication speed and range of the OPL 9712 may vary due to obstacles and radio wave conditions between the OPL 9712 and the device to which the OPL 9712 is connected.
9.3. Infrared Transmission (IrDA) Specifications 9.3.1. Thee CRD-9723 cradle enable the OPL 9712 to perform infrared transmission of data with IrDA Ver1.2 low power specification. Transmission speed 9.3.2. Default transmission speed is set at 115.2 kbps. However, you can easily change the transmission rate to 57.6 kbps, 38.4 kbps, 19.2 kbps, 4.8 kbps, or 2.4 kbps.
Opticon OPL 9712 Specifications Manual 11. Serial Number The serial number shown on the right is written on silver matte with black paper affixed to the backside of the OPL 9712. Figure 8: Serial number diagram...
Opticon OPL 9712 Specifications Manual 12. FCC Labels This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
13. Packaging Specifications 13.1. Individual Packaging Specification Place the OPL 9712 in a protection bag E, and pack it in the provided box. Then place the accessories into the box. Accessories: • 1 lithium-ion battery • 1 hand strap Close the box and affix a label to the side of the box.
Opticon OPL 9712 Specifications Manual 13.2. Labeling Figure 11: Labels When packing 50 pre-packaged data collectors, select a box size equal to 560 mm (W) by 490 mm (D) by 195 mm (H). Note: The “RO” mark labeled on the package tray or package box guarantees that the...
Keypad operating life: The keypad expected usability is 1,000,000 uses (cycles) when the key is pressed with 1 kgf force. The estimate of MTBF is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock. Figure 12: Shock test Opticon OPL 9712 Specifications Manual...
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: UFOOPL9712 Opticon OPL 9712 Specifications Manual...
2002/95 EC 16.6. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate. To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources (Japan), products that may contain Perchlorate materials should be properly labeled on the exterior of all outer shipping packages and/or in locations that otherwise satisfy the California Perchlorate Best Management Practices.
Do not use the data collector near a radio or a TV receiver. It may cause reception problems. • The data collector may be damaged by voltage drops. • The data collector may not perform properly in environments when placed near a flickering light, such as a computer monitor, television, etc. Opticon OPL 9712 Specifications Manual...
Need help?
Do you have a question about the OPL 9712 and is the answer not in the manual?
Questions and answers