Chapter 2 - Installation
Data
cable
Power
cable
Ethernet
cable
Figure 2-22: Connecting Data Cable When Using PoE (for 5 GHz Units Only)
2.5.1.3
DC Power Cable Connection (not applicable if using PoE)
The power cable is supplied with a specially designed sealing gland that should
replace the existing gland provided with the BreezeMAX Extreme BTS.
Cables are open ended at the Power Supply side.
To connect the power cable:
Remove the existing gland from the 48V connection on the BTS.
1
Attach the DC power cable with the already assembled gland to the 48V
2
connection on the BTS.
Separate the sealing gland nut from the gland body.
3
Use the dedicated tool to fasten the gland to the BTS.
4
Use the dedicated tool to fasten the sealing gland's nut on the gland body.
5
Connect the other end of the power cable to the 48VDC power source.
6
BreezeMAX Extreme
61
Cable Connections
System Manual