Alvarion BreezeMAX Extreme System Manual page 258

Hide thumbs Also See for BreezeMAX Extreme:
Table of Contents

Advertisement

Chapter 4 - Operation and Administration
Parameter
Number of Channels to Scan
Number of Channels for
Selection
Minimum Number of
Registered MSs before
Starting Tracking
Sector - Spectrum Analyzer
Spectrum Analyzer Support
Start Frequency
Stop Frequency
Scanning Time
Step
BS - General Parameters
BS Name
BS - MAC
Segment Number
Cell Number
Cell Radius
Map Repetition
BS - PHY
BreezeMAX Extreme
Table 4-28: BTS Parameters Summary
Range
Depends on Country Code Name and
bandwidth
1 to the number configured for the
Number of Channels to Scan (if Random
Channel Selection is enabled) or to the
number of channels in the Usable
Frequencies list (if Random Channel
Selection is disabled).
1 to 50
Enable
Disable
Depends on Country Code and
bandwidth
Depends on Country Code and
bandwidth
1 to 3600 (seconds)
Multiples of 5 MHz (5, 10, 15..)
Up to 32 printable characters
0-3
0-31. For cells with 4 sectors the range is
0-17.
8000-40000 (meter)
In current release only 8000 and 40000
are supported
1, 2, 4, 6.
237
Parameters Summary
Default
Run-Time
Updated
Depends on Country
No
Code Name and
bandwidth
1
No
1
No
Disable
Yes
The lowest available
Yes
frequency
The highest available
Yes
frequency
60
Yes
5
Yes
Null
Yes
0
No
0
No
40000
No
1
No
System Manual

Advertisement

Table of Contents
loading

Table of Contents