If set to Transparent, the value of the inner VLAN Priority will be used also as the
outer VLAN parameter in the uplink direction. No specific action is required at
downlink direction assuming that the inner VLAN is assigned properly.
The following Value parameter is applicable only if BE VLAN Priority Marking
Mode is set to Marking.
The default is Transparent.
4.8.2.2.6.3.6 BE VLAN Priority Value
Applicable only if VLAN Priority Marking Mode is set to Marking. Enables
configuration of the outer VLAN Priority to be applied in the uplink to packets in
BE connections.
A value in the range 0 to 7. The default is 0.
4.8.2.2.6.4
BS and ASN-GW Keep Alive
The BS and ASN-GW Keep Alive submenu enables viewing/updating the
parameters of the keep-alive mechanism between the BS and the external
ASN-GW:
4.8.2.2.6.4.1 Keep Alive Support
The Keep Alive Support parameter defines whether the keep alive mechanism is
disabled or enabled.
The default is Disable.
If Keep Alive Support is set to Disable the following parameters are not applicable
and are not presented.
4.8.2.2.6.4.2 Keep Alive Timer (Seconds)
The Keep Alive Timer parameter defines the time between PING transmissions to
the ASN-GW.
The range is from 60 to 180 seconds. The default is 60 seconds.
4.8.2.2.6.4.3 Keep Alive Interval (Seconds)
The Keep Alive Interval defines the time to wait for a keep-alive response from the
ASN-GW.
The range is from 1 to 30 seconds. The default is 5 seconds.
4.8.2.2.6.4.4 Maximum Number of Keep Alive Failures
The Maximum Number of Keep Alive Failures defines the maximum number of
keep-alive failures before reaching a decision that the ASN-GW is not reachable.
The range is from 1 to 10. The default is 3.