Immediate Upgrade Configuration Example (For Irf Mode) - HP A7500 Series Configuration Manual

Hide thumbs Also See for A7500 Series:
Table of Contents

Advertisement

CAUTION:
If the size of the Flash on the device is not large enough, delete the original system software images from
the Flash before downloading.
# Before upgrade, execute the save command to save the current configuration (configuration procedure
is omitted).
# Log in to the FTP server (The prompt may vary with servers.)
<Device> ftp 2.2.2.2
Trying 2.2.2.2 ...
Press CTRL+K to abort
Connected to 2.2.2.2.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(2.2.2.2:(none)):aaa
331 Give me your password, please
Password:
230 Logged in successfully
[ftp]
# Download the soft-version2.app and bootrom-version2.btw programs on the FTP server to the Flash of
the device.
[ftp] binary
[ftp] get soft-version2.app
[ftp] get bootrom-version2.btw
[ftp] bye
<Device>
# Upgrade Boot ROM of the active MPU (resides in slot 0).
<Device> bootrom update file bootrom-version2.btw slot 0
# Upgrade Boot ROM of the standby MPU (resides in slot 1).
<Device> copy bootrom-version2.btw slot1#flash:/bootrom-version2.btw
<Device> bootrom update file slot1#flash:/bootrom-version2.btw slot 1
# Specify the system software image for the next boot on the active MPU.
<Device> boot-loader file soft-version2.app slot 0 main
# Specify the system software image for the next boot on the standby MPU.
<Device> copy soft-version2.app slot1#flash:/soft-version2.app
<Device> boot-loader file slot1#flash:/soft-version2.app slot 1 main
# Reboot the device. The software version is upgraded now.
<Device> reboot
To check if the upgrade is successful after the device reboots, use the display version command.

Immediate upgrade configuration example (for IRF mode)

Network requirements
As shown in
of 1 and the slave has a member ID of 2. The active MPU of the master is in slot 0, and the standby
MPU of the master is in slot 1. The active MPU of the slave is in slot 0, and the standby MPU of the
slave is in slot 1.
Figure
47, the IRF fabric comprises two member switches: the master has a member ID
125

Advertisement

Table of Contents
loading

Table of Contents