Siemens SITRANS LR200 Instruction Manual page 72

Hide thumbs Also See for SITRANS LR200:
Table of Contents

Advertisement

Appendix G: menu structure
Identification
1. Identification
2. Configuration
3. Device
4. Statistics
Input
2. Input
1. Reset Filter
2. Standard Setup
3. Sensor Calibration
4. Measuring Limits
5. Linearization
6. Detailed Setup
Output
3. Output
See Output (page 67)
Page 66
SITRANS LR 200 (PROFIBUS PA) – INSTRUCTION MANUAL
Configuration
1. Device Address
2. Remote Lockout
3. Master Reset
4. Reset Fault
5. Menu Timeout
Device
1. Software Revision
2. Loader Revision
3. Hardware Revision
4. PROFIBUS Ident Number
5. Write Locking
6. Language
Statistics
1. Powered Hours
2. Poweron Resets
Standard Setup
1. Antenna
2. Response Rate
3. Echo Lock
Sensor Calibration
1. Sensor Unit
2. Calibration Type
3. Low Calibration Pt.
4. High Calibration Pt.
5. Unit (Level)
6. Low Level Point
7. High Level Point
8. Level Offset
9. Sensor Offset
A. Temperature Unit
Measuring Limits
1. Min. Measured Value
2. Max. Measured Value
3. Min. Sensor Value
4. Max. Sensor Value.
5. Process Temperature Min
6. Process Temperature Max
Linearization
1. PV (volume/level) Unit
2. Linearization/Tank Shape
3. Linearization Volume
4. Dimension A
5. Dimension L
Input
Detailed Setup
6. Detailed Setup
1. Failsafe
2. Volume
3. Echo select
4. Echo sampling
5. Range
6. Echo Quality
7. Auto False Echo
Suppression setup
8. TVT shaper
9. Rate
A.TB values
SITRANS LR 200 (PROFIBUS PA) – INSTRUCTION MANUAL
Failsafe
1. LOE Timer
Volume
Table A 1. Level 1
2. Volume 1
3. Level 2
4. Volume 2
5. Level 3
6. Volume 3
7. Level 4
8. Volume 4
Table B 1. Level 5
2. Volume 5
3. Level 6
4. Volume 6
5. Level 7
6. Volume 7
7. Level 8
8. Volume 8
Table C 1. Level 9
2. Volume9
3. Level 10
4. Volume 10
5. Level 11
6. Volume 11
Echo select
1. Algorithm
2. Confidence Threshold
3. Echo Marker
4. Shots
5. Velocity
6. Propagation Factor
Echo Sampling
1. Sampling up
2. Sampling down
3. Window
4. Window used
Range
1. Near Range
2. Far Range
Echo Quality
1. Echo confidence long
2. Echo strength
3. Noise average
4. Noise peak
5. Noise minimum
Auto False Echo Suppression setup
1. TVT Hover Level
2. Auto False Echo Suppression
3. Auto False Echo Suppression Distance
4. Shaper Mode
TVT Shaper
1. Shaper A (1-9)
2. Shaper B (10-18)
3. Shaper C (19-27)
4. Shaper D (28-36)
5. Shaper E (37 - 40)
Rate
1. Fill rate
2. Empty rate
TB Values
1. PV
2. SV1
3. SV2
7ML19985HP01

Advertisement

Table of Contents
loading