Panasonic KX-TD500 Programming Manual page 345

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

Error Code
E1059
VPS card duplicated.
Each physical number of the VPS Card (Jack 1-8) and VPS Card (Jack 9-12) must be
assigned uniquely.
E1060
You have exceeded the limit of VPS(DPT) port per DLC card.
There is a limit of 8 VPS(DPT) ports per DLC card.
E1061
You have exceeded the shelf limit of VPS(DPT) port.
There is a limit of 16 VPS(DPT) ports per shelf.
E2001
Invalid time format.
Please specify the time as Hour:[0]1-12, Minute:[0]0-59.
E2002
Assign the time of beginning and ending in a pair.
Cannot assign just the start time or just the end time of Lunch/Break service. Both must
be assigned as a pair.
E2005
Maximum entry number of System Speed Dialing exceeded.
The system provides up to 1000 / tenant, 2000 / system of System Speed Dialling
entries available to all extension users.
E2006
Cannot change System Speed Dialing Entries Maximum.
Please delete System Speed Dialling entries until there is less than the setting you want.
Then set System Speed Dialling Entries Maximum once again.
E2007
Invalid directory number for manager extension.
Only DN of an extension can be assigned as a manager extension. (FDN cannot be
assigned.)
E2008
Feature number is too long.
Feature numbers "Hundred Block Extension" or "Other PBX" can be set as the leading
1 or 2 digits of the extension number.
E2009
Cannot delete the Hundred Block Extension, which is currently in use as DN or
FDN.
Cannot delete the hundred block number. It's already used as DN or FDN. Please delete
the hundred block number after you remove the registrations of DN or FDN.
E2010
Feature number duplicated.
Feature numbers can be from 1 to 4 digits and shouldn't be any conflicts.
The following are examples of feature number conflicts.
Examples: N and NX, NXX / NM and NML ( NL is allowed.)
E2011
Out of range.
Overflow Timer should be assigned in the range of Second: 5-180.
"None" shows that Overflow Timer doesn't work.
E2012
Trunk group number duplicated.
Each trunk group in the Local Hunt Sequence must have a unique number.
Programming Guide
Error Message
Description
Programming Error Messages