Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Programming Guide
Card No.
XXX : E1 [ XXX : Card No. (101-314)]
Specifies the physical number of the E1 digital trunk card which
you are going to programme.
• 1.2 Slot Assignment (P/G)
Channel Type
Undefined
1.
Undefined
2.
DR2
3.
E&M-P
4.
E&M-C
Specifies the type of E1 interface per channel.
1.
Undefined: Not assigned.
2.
DR2: Digital signalling system-R2
3.
E&M-P: Pulsed E&M
4.
E&M-C: Continuous E&M
• 1.3 System Features (F/G)
– E1 Carrier
Group No.
Blank
1-48
Specifies the Trunk Group (1-48) to which the E1 port is assigned.
• 1.3 System Features (F/G)
– Trunk Group
• 3.2 Trunk Group (P/G)