Mitsubishi Electric QJ71LP21 Reference Manual page 310

Q corresponding melsecnet/h network system
Hide thumbs Also See for QJ71LP21:
Table of Contents

Advertisement

APPENDIX
No.
Name
3
Cyclic transmission start
SB0051
completion status
(81)
3
Cyclic transmission stop
SB0052
acknowledgment status
(82)
3
Cyclic transmission stop
SB0053
completion status
(83)
SB0054
Parameter receive status
(84)
SB0055
Received parameter error
(85)
3
SB0056
Communication status
(86)
SB0057
Parameter type
(87)
Operation designation at
fault of control station
SB0058
(88)
Operation designation at
fault of (multiplexed)
remote master station
SB0059
Low-speed cyclic
(89)
designation
SB0064
Reserved station
(100)
designation
SB0068
Communication mode
(104)
SB0069
Multiplex transmission
(105)
designation
3
Multiplex transmission
SB006A
status
(106)
3: Valid only when SB0047 is off. When it turns on (error), the last data are retained.
App - 6
Table 1 Special link relay (SB) list (Continued)
Description
Indicates the completion status of the cyclic transmission.
Off: Not completed (SB0002 is off)
On: Start completed (SB0002 is on)
Indicates the stop acknowledgment status of the cyclic
transmission.
Off: Not acknowledged (SB0003 is off)
On: Stop acknowledged (SB0003 is on)
Indicates the stop completion status of the cyclic transmission.
Off: Not completed (SB0003 is off)
On: Stop completed (SB0003 is on)
Indicates the parameter receive status.
Off: Receive completed
On: Not received
Indicates the status of the received parameters.
Off: Parameters normal
On: Parameters abnormal
Indicates the status of the transient transmission. (Valid when the
SB0047 is off.)
Off: Transient transmission by the control station
On: Transient transmission by the sub-control station
Indicates the parameter type.
Off: MELSECNET/10 parameter
On: MELSECNET/H parameter
On PLC to PLC network
Indicates the setting of "With data link by sub control station
when control station is down."
Off: Cyclic transmission made by sub control station when
control station fails.
On: Cyclic transmission not made by sub control station
when control station becomes faulty
On remote I/O network
Indicates the status of designating cyclic transmission when the
(multiplexed) remote master station fails.
Off: Cyclic transmission made by multiplexed remote sub-
master station when multiplexed remote master station
fails (multiplexed remote I/O network)
On: Cyclic transmission not made when remote master
station fails (remote I/O network)
Indicates whether or not there are any parameter settings for the
low-speed cyclic transmission.
Off: No settings
On: Settings exist
Indicates whether or not the station is reserved. (Valid when the
SB0049 is off.)
Off: No reserved station
On: Reserved station exists
Turns off when the SW0064 to SW0067 are all "0."
Indicates the link scan mode (status of supplemental settings of
the common parameters).
(Valid when the SB0049 is off.)
Off: Normal mode
On: Constant scan mode
Indicates the transmission designation status (status of
supplemental settings of the common parameters).
(Valid when the SB0049 is off.)
Off: Normal transmission designation
On: Multiplex transmission designation
Indicates the transmission status.
Off: Normal transmission
On: Multiplex transmission
MELSEC-Q
Use permitted/prohibited
Remote
Control
Normal
master
station
station
station
Optical Coaxial Optical Coaxial Optical Coaxial Optical Coaxial
Remote I/O
station
App - 6