PLC Setup
Cases when settings must be changed
You want to set the various parameters for the origin search func-
tion. (See note 4.)
You want to use the Serial PLC Link. (See note 4.)
Note
7-1-2
PLC Setup Settings
7-1-2-1
Startup Tab Page
Startup Hold Settings
Forced Status Hold Bit
Address in
Programming
Console
Word
Bit(s)
80
14
0: Cleared
1: Retained
Default: 0
266
1. CJ1-H CPU Units only.
2. CJ1-H and CJ1M CPU Units only.
3. CJ1-H and CJ1 CPU Units only.
4. CJ1M CPU Units only.
All non-binary settings in the following tables are hexadecimal unless other-
wise specified.
Settings
This setting determines whether or not the
status of the Forced Status Hold Bit
(A50013) is retained at startup.
When you want all of the bits that have been
force-set or force-reset to retain their forced
status when the power is turned on, turn ON
the Forced Status Hold Bit and set this set-
ting to 1 (ON).
Setting(s) to be changed
• Pulse outputs 0/1: Origin search, origin return ini-
tial speed
• Pulse outputs 0/1: Origin search high speed
• Pulse outputs 0/1: Origin search proximity speed
• Pulse outputs 0/1: Origin compensation value
• Pulse outputs 0/1: Origin search acceleration rate
• Pulse outputs 0/1: Origin search deceleration rate
• Pulse outputs 0/1: Limit input signal type
• Pulse outputs 0/1: Origin proximity input signal
type
• Pulse outputs 0/1: Origin input signal type
• Pulse outputs 0/1: Positioning monitor time
• Pulse outputs 0/1: Origin return target speed
• Pulse outputs 0/1: Origin return acceleration rate
• Pulse outputs 0/1: Origin return deceleration rate
• RS-232C Communications Port: Serial Communi-
cations Mode
• Serial PLC Link: Format
• Serial PLC Link: Number of words to send
• Serial PLC Link: Maximum unit number
• Serial PLC Link: Polled Unit unit number
Function
Section 7-1
Related
When set-
flags and
ting is read
words
by CPU Unit
A50013
At startup
(Forced Sta-
tus Hold Bit)