Omron CJ1G/H-CPU series Operation Manual page 115

Sysmac cj series
Hide thumbs Also See for CJ1G/H-CPU series:
Table of Contents

Advertisement

Specifications
Item
CIO
I/O Area
1,280: CIO 000000 to CIO 007915 (80 words from CIO
(Core
0000 to CIO 0079)
I/O)
The setting of the first word can be changed from the
Area
default (CIO 0000) so that CIO 0000 to CIO 0999 can be
used.
I/O bits are allocated to Basic I/O Units.
Link Area
3,200 (200 words): CIO 10000 to CIO 119915 (words CIO
1000 to CIO 1199)
Link bits are used for data links and are allocated to Units
in Controller Link Systems.
CPU Bus Unit
6,400 (400 words): CIO 150000 to CIO 189915 (words CIO
Area
1500 to CIO 1899)
CPU Bus Unit bits store the operating status of CPU Bus
Units.
(25 words per Unit, 16 Units max.)
Special I/O Unit
15,360 (960 words): CIO 200000 to CIO 295915 (words
Area
CIO 2000 to CIO 2959)
Special I/O Unit bits are allocated to Special I/O Units.
(10 words per Unit, 96 Units max.)
Note Special I/O Units are I/O Units that belong to a spe-
Serial PLC Link
1,440 (90 words): CIO 310000 to CIO 318915 (words
Area (CJ1M
CIO 3100 to CIO 3189)
CPU Units
only)
DeviceNet Area 9,600 (600 words): CIO 320000 to CIO 379915 (words CIO
3200 to CIO 3799)
DeviceNet bits are allocated to Slaves for DeviceNet Unit
remote I/O communications when the Master function is
used with fixed allocations.
Fixed allocation
setting 1
Fixed allocation
setting 2
Fixed allocation
setting 3
The following words are allocated to the Master function
even when the DeviceNet Unit is used as a Slave.
Fixed allocation
setting 1
Fixed allocation
setting 2
Fixed allocation
setting 3
Internal I/O
4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to
Area
CIO 1499)
37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to
CIO 6143)
These bits in the CIO Area are used as work bits in programming to
control program execution. They cannot be used for external I/O.
82
Specifications
cial group called "Special I/O Units." Example:
CJ1W-AD081 Analog Input Unit
Outputs: CIO 3200 to CIO 3263
Inputs: CIO 3300 to CIO 3363
Outputs: CIO 3400 to CIO 3463
Inputs: CIO 3500 to CIO 3563
Outputs: CIO 3600 to CIO 3663
Inputs: CIO 3700 to CIO 3763
Outputs: CIO 3370 (Slave to Master)
Inputs: CIO 3270 (Master to Slave)
Outputs: CIO 3570 (Slave to Master)
Inputs: CIO 3470 (Master to Slave)
Outputs: CIO 3770 (Slave to Master)
Inputs: CIO 3670 (Master to Slave)
Section 2-1
Reference
The CIO
9-3 I/O Area
Area can
be used
as work
bits if the
bits are
not used
9-4 Data Link Area
as shown
here.
2-5-3 Communications
Network System
Controller Link Unit
Operation Manual
(W309)
9-5 CPU Bus Unit Area
Operation Manual for
each CPU Bus Unit
9-6 Special I/O Unit
Area
Operation Manual for
each Special I/O Unit
9-7 Serial PLC Link
Area
DeviceNet Unit Opera-
tion Manual (W380)
9-2-2 Overview of the
Data Areas

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1m-cpu seriesCj1g-cpu series

Table of Contents