Water-Cooling; Table 1-9 Technical Data For The Cooling Circuit - Siemens 1FT6031-4AK71-4AH0-Z Manual

Servo motors
Table of Contents

Advertisement

1.7.3

Water-cooling

The power loss generated by the motor is dissipated using a water cooling system. The
machinery construction company must connect-up a cooling system (e.g. heat exchanger).
The rated motor torques, specified in the motor data sheets apply for water-cooled operation
and a water intake temperature of < 30 °C.
Notice
If the motor is operated without water cooling, then the rated motor torque is reduced as a
function of the heat losses which can be dissipated by convection and radiation. In this case,
the data for non-ventilated operation apply.
Note
It is not possible to retrofit a motor for water cooling.
The cooling medium must be pre-cleaned and filtered in order to prevent the cooling circuit
from becoming blocked. The maximum permissible particle size after filtering is 100 mm.
Cooling circuit
Notice
If current is flowing through the motor, then the cooling circuit must be activated.
Table 1-9
Pressure drop, intake/return: < 0.1 bar
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
Technical data for the cooling circuit
Motor type
Water flow rate [l]
1FT6062
1FT6064
1FT6082
1FT6084
1FT6086
1FT6105
1FT6108
1FT6132
1FT6134
1FT6136
1FT6138
1FT6163
1FT6168
Max. permissible
pressure [bar]
0.2
2.5
0.26
2.5
0.4
2.5
0.5
2.5
0.6
2.5
1.1
2.5
1.5
2.5
2.1
6.0
2.4
6.0
2.7
6.0
3.1
6.0
4.7
6.0
5.7
6.0
Motor Description
1.7 Cooling
Flow rate
[l/min]
5
5
5
5
5
5
5
8
8
8
8
10
10
1-23