Total Mode - Rice Lake MSI-8000 Technical Manual

Hide thumbs Also See for MSI-8000:
Table of Contents

Advertisement

1. Press
F1
and
2. Press
F2
to scroll to
3. Press
F1
. The currently saved total mode displays.
4. Press
F2
to scroll through the choices.
5. With choice displayed, press
to save and exit to weighing mode.
6. Press
ZERO

4.8.2 Total Mode

For the accumulation of multiple weighments, the Total function uses the displayed load, so gross and net readings
can be added into the same total.
There are four modes of totalizing, a manual and three auto modes.
All modes require that the weight on the scale return below 0.5% (relative to full scale) of
before the next weighment can be added. Applied weight must be ≥1% of full scale above
before it can be totaled.
Manual Total
Manual Total () adds a current weight to a previously accumulated value manually. To add weight to the total
it must be greater than 1% of capacity and not yet totaled. This assures that a weight on the scale is only added to
the total once.
1. Program a
to
F-key
2. With the weight to be added on the scale, press
was accepted and the
number of samples is displayed for two seconds.
3. Repeat steps 1 & 2 until all weight samples have been added.
Total Mode will not function while the scale is in motion, ensure
stable readings, increase the filter setting or increase the size of the scale division (d) in the Init Cal procedure.
The F-Total functions as View Total only until the 1% threshold is exceeded to allow the addition to the total
value.
Auto Total
This mode has three variations which are programmed in the Setup menu.
Program an
to
F-key
AUTO TOTAL
Setpoint

Auto Load – ensures any settled load above the Rise Above threshold will be automatically totaled. The scale must fall
below the Drop Below threshold before the next total is allowed.

Auto Last – takes the last settled weight to auto total with. The total occurs only once the scale goes below the
threshold. This allows the load to be adjusted without a total occurring. Once the load is removed, the scale uses the
last settled reading for total.

Auto High – uses the highest settled reading. This is useful for loads that can't be removed all at once.
Set Total Mode
1. Press
F1
and
2. Press
F2
to scroll to

simultaneously.
POWER

.
F1
to select.

. See Section 4.2 on page 9.
annunciator lights. Then the total weight is displayed for five seconds and the
TOTAL
, it functions as
Auto Total On
Table 4-5. Auto Load Selections

simultaneously.
POWER

.
displays.

displays.
. The acknowledge LED blinks to indicate the weight
F-Total
is on. If the system fails to achieve
/
. See Section 4.2 on page 9.
Auto Total Off
Description
will display.
or
Gross Zero
Net Zero
or
Gross Zero
Net Zero
Setup
15

Advertisement

Table of Contents
loading

Table of Contents