Primary And Secondary Units; Display Type And Model; Learn Mode (Autolink) - Rice Lake SURVIVOR IQ F Series Installation Manual

Flip digit remote displays
Table of Contents

Advertisement

3.2.2

Primary and Secondary Units

Switches DSW2-1 through DSW2-4 set the primary
and secondary annunciators for the remote display.
Using these switches, the lb and kg annunciators can
be assigned to designate pounds, kilograms, tons, or
metric tons (megagrams). Decals included with the
remote display can be used to change annunciator
labeling to show tons (T), metric tons (t), or
megagrams (Mg).
Actual function of the lb and kg annunciators depends
on the units information included in the indicator
serial stream.
To Configure...
Parameter
Primary units
Secondary units
Model
Display type

Learn mode (AutoLink)

enable
3.2.3

Display Type and Model

Switches DSW2-5 through DSW2-7 set the display
type and model. DSW2-7 must be off for all F-Series
remote displays.
3.2.4
Learn Mode (AutoLink)
The F-Series remote displays incorporate a software
feature called AutoLink . The AutoLink learn mode
function examines the serial data stream sent from the
attached indicator and attempts to determine the data
structure and format used by the indicator.
NOTE:
If learn mode is enabled, switches DSW1-4
through DSW1-8 and all DSW4 switch settings are
ignored.
Use the following procedure to learn the indicator
serial data stream:
Value
1
2
Pounds
OFF
OFF
Kilograms
OFF
ON
Metric tons
ON
OFF
Tons
ON
ON
Pounds
Kilograms
Metric tons
Tons
F15
F40
F60
Flip digit
LCD
Off
On
Table 3-3. DSW2 Switch Settings
Primary
Secondary
units
units
1
2
3
4
DSW2
Figure 3-1. DSW2 Switch Definitions
DSW2
3
4
5
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
1. Set DIP switch DSW2-8 on.
2. With wiring and configuration complete for
both the indicator and the remote display,
power on the indicator, then the remote
display.
3. When the power-up self-test is complete,
press the
LEARN MODE
underside of the display enclosure. (See
page 10 for information about the self-test
procedure.)
4. The display shows the message
examines the serial data stream sent from the
attached indicator. The
shifted off the display as the data stream
format is learned.
5. Next, the baud rate is shown in the format
xxx
, where
xxx
is the learned baud rate with
Model
5
6
7
8
6
7
8
ON
OFF
ON
OFF
ON
switch on the
while it
LOAd
LOAd
message is
b
Configuration
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Survivor iq f15Survivor iq f40Survivor iq f60

Table of Contents