4.0

Setup

The front panel keys will work, as shown below, when navigating through the menus during setup.
• Press
F1
to enter or select a parameter.
• Press
F2
to scroll through the parameters.
• To enter a decimal point, press
to save and go back one level or to weigh mode.  displays briefly.
• Press
ZERO
• If a wrong value is entered, press
• Press
to exit without saving changes.
POWER
4.1

Setup Menu

To enter the setup menu, press the
Parameters
Choices



























8
MSI-8000 RF Remote Display
while the digit is blinking.
POWER
to step back one digit and press
ZERO
and
F2
POWER
Function key 1 – Configurable to listed parameters, see Section 4.2 on page 9; Default 
Function key 2 – Configurable to listed parameters, see Section 4.2 on page 9; Default 
No function is assigned. The F-Key is disabled
Test – runs an LCD test, see Section 4.2.1 on page 9
Total – accumulates multiple weighments, see Section 4.2.2 on page 10
View total – activates the total weight display followed by the number of samples
See Section 4.2.2 on page 10
Net/Gross – toggles between Net and Gross modes, see Section 4.2.3 on page 10.
RF Remote Learn – used for programming a RF remote, see RF remote manual for more details
Peak Hold – automatically updates the display when a higher peak weight reading is established
See Section 4.2.4 on page 10.
2 Units – switches the force units between lb and kg. See Section 4.2.5 on page 10.
5 Units – scrolls through all available units: lb, kg, Tons (US Short), Metric Tons, and kiloNewtons.
See Section 4.2.5 on page 10.
Hi Res – the unit is more sensitive to motion and movement resulting in a less stable display
See Section 4.2.6 on page 10.
Print – outputs a configured text string to the RS-232 port on the base of the Dyna-Link.
See Section 4.2.7 on page 11.
Tare – not used, MSI-8000HD has a dedicated tare key
Scan – displays RF connected channels in order
Total Remote Devices – displays the summed weight of RF connected sensors. See Section 4.2.8
on page 11.
Auto Off – prolongs the battery life of the scale by turning power off after the set time (in minutes)
that the scale is not in use.
See Section 4.3 on page 11
Greater Than – setpoint will trigger when the tension exceeds the value.
Less Than – setpoint will trigger when the tension is less than the value.
Off - the setpoint parameter is disabled.
Table 4-1. Setup Menu Parameter Descriptions