5.0

Calibrating a Scale/Dyna-Link 2

The MSI-8000 remote display can be used for calibrating MSI ScaleCore-based crane scales and dynamometers,
including MSI-3460 Challenger 3, MSI-4260 Port-A-Weigh or MSI-7300 Dyna-Link 2.
They can be calibrated using standard precision test weights. It is required that the weight used is at least 10% of
full capacity in order to achieve rated accuracy.
When adequate test weights are not available, the scale/dynalink can be calibrated using a constant calibration 
() See Section 5.1.2.
If the linked scale/Dyna-Link is sealed for NTEP approval, the seal will need to be broken and the calibration
switch on the linked scale/Dyna-Link will need to be pressed for the MSI-8000 to perform the calibration.
5.1

Initial Calibration

Initial calibration is used to setup units, capacity and resolution (d) required for the load cell.
Initial calibration is also performed after a calibration reset which deletes all calibration.
1. Press
and
ZERO
2. Press the programmed
,  displays.
3. Press
F1
4. Press
F1
. The default units are displayed.
5. Press
F2
to scroll through the available units.
6. With desired unit displayed, press
7. Press
. The default capacity is displayed.
F1
8. To enter a different capacity, press
9. Press
F2
to scroll through numbers and
10. When all numbers have been selected, press
11. Press
F1
. The default display divisions are displayed.
12. Press
F2
to scroll through the available display divisions.
13. With desired display division displayed, press
14. Proceed with the routine calibration, starting with step 2 of Section 5.1.1.
5.1.1

Routine Calibration

For maintenance and routine calibration use the following steps.
1. Press the configuration switch.  is displayed.
,  displays.
2. Press
F1
3. Remove all weight from the scale.
simultaneously.  displays.
F2
to scroll to the load cell to be calibrated.
F-Key
to select.  is displayed.
F1
F2
.
F1
to save the selected numbers.
to store the number.  displays.
F1
to select.  displays.
F1
Calibrating a Scale/Dyna-Link 2