Total; Net/Gross; Peak Hold; Units - Rice Lake MSI-8000 Technical Manual

Hide thumbs Also See for MSI-8000:
Table of Contents

Advertisement

Internal tests are also performed, if any test fails, an error code is displayed. See Section 7.2 on page 35 for a
description of all error codes.

4.2.2 Total

1. Ensure the total mode has been programmed in the setup menu. If this has not been setup the
assigned to
will not work.
Total
2. Program an
F-key
3. Press
to perform the total function that was set in Section 4.8.2 on page 15.
Fx-Total

4.2.3 Net/Gross

Program an
to
F-key
NetGross
Press
to toggle between gross and net (gross minus tare).
Fx-NetGross
established.
The operator can switch back to gross from net without clearing the tare value. Only clearing or setting a new tare
will change the tare value held before switching into Gross Mode.

4.2.4 Peak Hold

Peak hold uses a high speed mode of the A/D converter allowing it to capture transient loads at a far higher rate
than typical Dynameters.
• Peak Hold is cleared and enabled by pressing
• When a new peak is detected, the
• The accuracy of the system in peak hold is slightly reduced to 0.2 percent of Capacity + 5d.
• The filter setting is turned off while in peak hold mode to ensure the fastest acquisition rate.
Example
The Peak Hold function is useful in Dynamic and Fall tests. Common tests include Overall Breaking
Strain (OB€), Breaking Force, and Cycled Breaking Strain.
Capture Peak Force:
1. Program an
F-key
2. Prepare the stand test and test sample.
3. Press
.
ZERO
4. Press
, confirm that
Fx-P-HLd
A small jump in the reading may occur depending on the stability of the test device.
5. Apply the test weight. The
6. Remove the weight and the peak value is recorded.
7. To run a new test, press

4.2.5 Units

Program an
to
. See Section 4.2 on page 9.
F-key
Unit
Press
to set the units parameter to units required for display.
Fx-Unit

4.2.6 Hi-Res

Only available with the MSI-7300 Dyna-Link (refer to the Dyna-Link manual PN 152160)
When set to on, the filter is automatically set to the
This will have a small effect on settling time. When set to off, the filter setting resets to the previous filter setting.
Program an
to
F-key
HiRes
10
MSI-8000 RF Remote Display
to
. See Section 4.2 on page 9.
Total
. See Section 4.2 on page 9.
LED will flash three times.
Fx
to
. See Section 4.2 on page 9.
P-HLd
is lit on the display.
Pk
LED will blink three times when a new peak ID is detected
Fx
to clear the peak value. Repeat steps 3 to 6.
Fx-P-HLd
Hi-1
. See Section 4.2 on page 9.
Fx-NetGross
Fx-P-HLd.
setting (if
is already set, then the filter is not changed).
Hi-2
F-Key
only functions if a tare has been

Advertisement

Table of Contents
loading

Table of Contents